January 2012 6.5 Analog Axes 669
6.5 Analog Axes
The parameter object
CfgAxisAnalog is not required for:
• Virtual axes (MP_axisMode = Virtual)
• Axes that are for display only (MP_axisMode = Display)
• Digital axes (MP_axisHw = CC or None)
In CfgAxis/axisHw = Analog, analog closed-loop axes are defined as such and
are described in the parameter object CfgAxisAnalog (see "Controller
parameters for analog axes" on page 902).
Analog output
In MP_analogOutput, you define the number of the analog nominal-value
output at connector X8 or X9.
MP_analogOutput
Speed command output of axis or spindle
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: none
No analog output assigned
analog Output 1...13
Analog outputs 1 to 6 (connector X8 on MC)
Analog outputs 1 to 4 (CMA-H 04-04-00)
Analog outputs 7 to 13 (connector X9 on MC 4xx)
Default: analog Output 1
Access: LEVEL3
Reaction: RUN
Connector X9 is only available on the MC 422x hardware with 10 control loops
and can therefore not be used on the MANUALplus 620.
Settings in the configuration editor MP number
Axes
ParameterSets
[Key name of the parameter set]
CfgAxisAnalog
analogOutput
maxFeedAt9V
400101
400105