1404 HEIDENHAIN Technical Manual MANUALplus 620
7.11.8 Transfer of data to the PLC
Transferring
spindle data to the
PLC
The two machine parameters MP_stoppingAngle and
MP_maxSpeedSpindle are used to transfer information about the spindle to
the PLC program. Use the dialog "Set T, S, F" to enter values for the stopping
angle [°] and the maximum spindle speed [1/min]. The PLC can manipulate the
two values once the dialog is closed.
MP_stoppingAngle
PLC operand for transfer of the spindle stopping angle
Available from NCK software version: 597110-01.
Format: String
Input: Max. 500 characters
Enter the name of a PLC operand (double word) with which the
stopping angle of the spindle is transferred to the PLC.
Default: For HEIDENHAIN basic PLC program:
NP_DG_Transfer_Stopping_Angle
Access: LEVEL1
Reaction: NOTHING
MP_maxSpeedSpindle
PLC operand for transfer of the maximum spindle speed
Available from NCK software version: 597110-01.
Format: String
Input: Max. 500 characters
Enter the name of a PLC operand (double word) with which the
maximum spindle speed is transferred to the PLC.
Default: For HEIDENHAIN basic PLC program:
NP_DG_Transfer_Speed_Limit
Access: LEVEL1
Reaction: NOTHING
Settings in the configuration editor MP number
System
PLC
CfgPlcSymName
stoppingAngle
maxSpeedSpindle
dbLoadDisplay
readTsfData
displayMode
setToolPlace
116101
116102
116103
116104
116105
116106

Table of Contents