690 HEIDENHAIN Technical Manual MANUALplus 620
6.8 Lubrication Pulse
The parameter object CfgPositionLimits is not required for:
Virtual axes (MP_axisMode=Virtual)
Axes that are for display only (MP_axisMode=Display)
In MP_lubricationDist, you define the traverse distance at which the
lubrication pulse for the axis guideways is to be output. The NC reports in
NN_AxLubricationPulse when the entered distance in an axis has been
exceeded.
Reset PP_AxLubricationDistReset after lubrication. This resets the
distance counter to 0.
MP_lubricationDist
Path-dependent lubrication of axis
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 000 000 to + 100 000 [mm] or [°]
0= no output of lubrication pulse to PLC
Default: 100 [mm] or [°]
Access: LEVEL3
Reaction: RUN
Settings in the configuration editor MP number
Axes
ParameterSets
[Key name of the parameter set]
CfgPositionLimits
lubricationDist 400503
After the MANUALplus 620 has been reset, the accumulated distance is
reset.
PLC operand / Description Ty p e
NN_AxLubricationPulse
Lubrication pulse: Value in MP_lubricationDist
exceeded
0: Value not exceeded
1: Value exceeded
M
PP_AxLubricationDistReset
Reset the accumulated distance:
0: Do not reset accumulated distance
1: Reset accumulated distance
M