604 HEIDENHAIN Technical Manual MANUALplus 620
5.2 Overview of the PLC Operands
5.2.1 PLC operands of the General Data group
Operand Description SW
version
Page
General – Control configuration
D NN_GenOmgCount Number of configured operating mode
groups
597 110-01 –
D NN_GenChnCount Number of configured machining channels 597 110-01 614
D NN_GenAxCount Number of configured logical axes
(including spindles)
597 110-01 615
D NN_GenSpiCount Number of configured spindles 597 110-01 999
General – Control status
D NN_GenOmgManual Selected operating mode group for manual
control
597 110-01 1236
D NN_GenChnManual Selected machining channel for manual
control
597 110-01 1252
D NN_GenSpiManual Selected spindle for manual control 597 110-01 1252
M NN_GenCycleAfterPowerOn
(M4172)
First PLC scan after power on 597 110-01 1314
M NN_GenCycleAfterPlcStop
(M4173)
First PLC scan after interruption of the PLC
program
597 110-01 1314
M NN_GenCycleAfterReConfig
(M4174)
First PLC scan after changing of the
configuration data
597 110-01 1314
M NN_GenNcInitialized
(M4184)
Control is being initialized (after start-up
cycles)
597 110-01 1314
M NN_GenNcEmergencyStop
(M4178)
Control in external emergency stop state 597 110-01 990
General – Error handling
M NN_GenApiModuleError
(M4203)
An error occurred while using an API
module.
597 110-01 –
D NN_GenApiModuleError
Code
(W1022)
Error code that occurred while using an API
module.
597 110-01 –
M PP_GenReactApiModuleError Perform the configured reaction to errors in
an API module: The reaction defined in
CfgPlcOptions apiErrorReaction is only
performed if this marker is set.
597 110-01 –