January 2012 6.22 Diagnosis with the Online Monitor (OLM) 1165
6.22.3 Screen layout
Display of variables Example of screen layout when variables are displayed:
The OLM lists the variable designations, status designations, etc. in the dark-
highlighted boxes of the "main window."
The white-highlighted boxes contain the variable values. The OLM displays
the values of two axes or channels.
The axis designation or channel designation defined in the parameters is
shown in the column heading.
Parameter for axis designation:
MP_System/CfgAxes/axisList(axisId)
Parameter for channel designation for IPO:
MP_ChannelGroup/CfgChannelGroup/Machining/ChannelList
Parameter for channel designation for SimIpo:
MP_ChannelGroup/CfgChannelGroup/Simulation/ChannelList
The term Index n in the column heading means that no axis or no channel is
defined for this index.