EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 1166

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1166 HEIDENHAIN Technical Manual MANUALplus 620
The following general data is displayed in the bottom display line:
Connected: Indicates the software or function area to which the OLM is
connected
•Ipo
•SimIpo
•PLC6
none: No connection
IpoCounter: Counts the IPO clock pulses
Note: The contents of the IpoCounter are also stored for trace information
and error messages.
Ax/Chn-Number: Logical axis number or channel number (depends on the
selected function)
Number at left: Left column
Number at right: Right column
If the number of variables displayed exceeds the capacity of the main window,
use PageDown/PageUp to scroll to the next/previous group of variables. One
group consists of eight displayed variables.
Units The OLM displays data in the following units:
Linear axes
For position, length, etc: in [mm]
For speed: in [mm/s]
For acceleration: in [mm/s
2
]
Rotary axes (spindles)
For position, etc: in [°]
For speed: in [°/s]
For acceleration: in [°/s
2
]
Selecting axes and
channels
To select axes or channels, proceed as follows:
Press CTRL + UP ARROW / DOWN ARROW to influence the left column.
CTRL + UP ARROW: Display the next axis/channel.
CTRL + DOWN ARROW: Display the previous axis/channel.
Press ALT + UP ARROW / DOWN ARROW to influence the right column.
ALT + UP ARROW: Display the next axis/channel.
ALT + DOWN ARROW: Display the previous axis/channel.
Press UP ARROW / DOWN ARROW (without CTRL or ALT) to influence
both columns.
UP ARROW: Display the next axes/channels.
DOWN ARROW: Display the previous axes/channels.

Table of Contents