250 HEIDENHAIN Technical Manual MANUALplus 620
3.21 Adapters for Encoder Signals
Encoder signals with 11 µA
PP
or TTL levels can be adapted to the 1 V
PP
inter-
face with HEIDENHAIN adapter connectors.
Please note:
The adapters adjust only the levels, not the signal shape.
The contamination signal of the square-wave encoder cannot be
evaluated.
A square-wave signal can be subdivided no more than 4-fold.