January 2012 4.5 Allocation of Configuration Data 379
4.5 Allocation of Configuration Data
The configuration data is saved in several files with the extension .cfg (see
"Managing configuration files" on page 345). Paths saved in the file
configfiles.cfg refer to these files.
This allocation has already been specified by HEIDENHAIN when the software
is delivered, but it can be adapted by the OEM to his requirements.
Allocation of configuration data
O:\config contains the following data:
configfiles.cfg Paths to the configuration data
version.cfg Version number of the update rules (JH, OEM)
O:\config\lathe\manplus contains the following data:
aggregate.cfg Data for the aggregates
axis_*.cfg Each drive has its own
configuration file. This way
you can change the drive easily.
ch1.cfg Data for the machining channel
configVersion.cfg Directory path of the config. data
dashboard.cfg Dashboard settings
KeyList.cfg Configuration of the system key names
kin_ch1_s1.cfg Old kinematics description
kinem*.cfg New kinematics description
oem.cfg General data for systems and channels
oempassword.cfg OEM-specific password settings, e.g.
for file and directory release or special
config data views.
oemtable.cfg OEM-specific settings for tables
plc.cfg Config. data for the PLC run-time system
plc_attr.cfg Config. data for PLC user parameters
plc_oem.cfg PLC parameters that are relevant for the OEM,
e.g.
MP_stoppingAngle and
MP_maxSpeedSpindle
plc_user.cfg PLC user parameters
proc_data.cfg Data for the machining mode of operation
runtime.cfg General data for the run-time system of the
control (reserved for HEIDENHAIN)
simu.cfg Simulation settings
table.cfg General settings for tables
table_mplus.cfg MANUALplus 620 specific table
settings
th1.cfg Configuration of the 1st tool holder
UpdateOemRel*.cfg OEM-specific update rules for PLC
parameters
V:\config contains the following data:
mptransfer.cfg Configuration of network settings
user.cfg General user parameters
user_ch1.cfg User parameters for the machining channel