378 HEIDENHAIN Technical Manual MANUALplus 620
Now you can undo the linking of entities, as required. This means you enter
values that deviate from the original set of parameters. Select the desired
entity and press the MORE FUNCTIONS soft key and then the INSERT soft key.
The yellow arrow then disappears.
Select the memory file via the pull-down menu.
Save your changes with the SAVE soft key.
The parameter set has now been created with the KeySynonym function,
and can be used.
MP_relatedTo
Link to key name
Available from NCK software version: 597 110-01.
Format: String
Input: Max. 18 characters
The synonym name refers to the key name specified here.
The data of the parameter object with the indicated key name
are used for the parameter object with the synonym name.
Example:
CH_SIM uses the same data as CH_NC
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_excludeList
List with configuration objects to be excluded
Available from NCK software version: 597 110-01.
Format: Array [0...49]
Input: Name of configuration objects; example:
CfgPositionLimits
Cancel the reference at CfgKeySynonym/relatedTo for the
entered parameter objects.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET