January 2012 7.2 Machine Display in the Dashboard 1289
7.2.1 Assigning dashboards to the operating modes
The control displays the dashboard for the active operating mode. If no
dashboard is defined for an operating mode, the default dashboard is
displayed.
Specify the default dashboard with the MP_defaultDashboard parameter
If desired, assign one or more dashboards to an operating mode
Dashboard
switchover
The soft key can be used to switch between the dashboards entered in
MP_opmodeManual and MP_opmodeAutomatic depending on the
operating mode. Up to 40 dashboards can be configured for the Manual and
Automatic operating modes. If the last dashboard in the list is active, the first
dashboard is jumped to. The prerequisite is that all dashboards entered in the
list are also configured under CfgDashboard.
MP_defaultDashboard
Default dashboard
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name of a dashboard configured under System/
DisplaySettings/CfgDashboard
Default: DB_DEFAULT
Access: LEVEL3
Reaction: RUN
Settings in the configuration editor MP number
Channels
ChannelSettings
[Key name of the machining channel]
CfgChannDashboard
defaultDashboard
opmodeStartup
opmodeReference
opmodeManual
opmodeManualLarge
opmodeMDI
opmodeAutomatic
opmodeAutomaticLarge
opmodeSGTest