1290 HEIDENHAIN Technical Manual MANUALplus 620
MP_opmodeStartUp
Dashboard for start-up phase
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name of a dashboard configured under System/
DisplaySettings/CfgDashboard
Default: DB_STARTUP1
Access: LEVEL3
Reaction: RUN
MP_opmodeReference
Dashboard for the Reference operating mode
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name of a dashboard configured under System/
DisplaySettings/CfgDashboard
Default: DB_REFER1
Access: LEVEL3
Reaction: RUN
MP_opmodeManual
Dashboard for the Manual operating mode
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name of a dashboard configured under System/
DisplaySettings/CfgDashboard
Default: DB_MANUAL1
Access: LEVEL3
Reaction: RUN
MP_opmodeMDI
Dashboard for the MDI operating mode
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name of a dashboard configured under System/
DisplaySettings/CfgDashboard
Default: No value, parameter optional
Access: LEVEL3
Reaction: RUN