1360 HEIDENHAIN Technical Manual MANUALplus 620
7.7.3 Compensation for potentiometers
MP_overrideFullRatio allows you to compensate voltage losses.
MP_overrideFullRatio
Compensation for cable losses of the override potentiometer
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.5000 to 1.0000
Default: 0.5 (optional parameter)
Access: LEVEL2
Reaction: NOTHING
Use MP_overrideDelta and MP_overrideIntegDelta to influence the
sensitivity of the override potentiometers. MP_overrideDelta suppresses
short-term fluctuations and MP_overrideIntegDelta compensates the signal
drift.
MP_overrideDelta
Compensation for thermal noise in override potentiometers
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.00010 to 0.10000
Default: 0.0001 (optional parameter)
Access: LEVEL2
Reaction: NOTHING
MP_overrideIntegDelta
Compensation for thermal noise in override potentiometers
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.00010 to 1.00000
Default: 0.0001 (optional parameter)
Access: LEVEL2
Reaction: NOTHING
Settings in the configuration editor MP number
System
PLC
CfgPlcPeriphery
overrideFullRatio
overrideDelta
overrideIntegDelta
103406
103407
103408