January 2012 7.7 Override 1359
Rapid traverse 
override
 In the channel-sensitive parameter object CfgPlcOverrideR, create a 
parameter set for each machining channel (slide) to which a rapid traverse 
override is to apply.
MP_minimal
Minimum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value 
Input: 0.00 to 100.00 [%]
Default: 0
Access: LEVEL3
Reaction: RESET
MP_maximal
Maximum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value 
Input: 0.00 to 200.00 [%]
Default: 150
Access: LEVEL3
Reaction: RESET
MP_source
Source for override values
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name for override device from CfgPlcOverrideDev
Default: PotentiometerF
Access: LEVEL3
Reaction: RESET
You can change the percentage through the PLC:
 Enter the desired percentage in PP_ChnRapidFeedOverride. The NC 
immediately takes over the new value.
Settings in the configuration editor MP number
Channels
ChannelSettings
[Key name of the machining channel]
CfgPlcOverrideR
minimal
maximal
source
202001
202002
202003
PLC operand / Description Ty p e
NN_ChnRapidFeedOverrideInput
Rapid traverse override set [%]
D
PP_ChnRapidFeedOverride
Rapid traverse override entered by the PLC [%]
D