1422 HEIDENHAIN Technical Manual MANUALplus 620
7.11.13 Settings for the simulation
If an NC program ends with M99, the control uses MP_restartAtM99 to
check whether the simulation of the NC program should be repeated.
Application example: Continuous simulation for exhibitions, etc.
MP_restartAtM99
Assign tool holder to an inner/outer pitch circle
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: on
If M99, then the NC program is simulated again.
off
If M99, then the NC program is not simulated again.
Default: off
Access: LEVEL1
Reaction: NOTHING
MP_pathDelay allows you to influence the speed of the simulation. After
output of a traversed distance, the control waits for the time entered in "path
delay."
MP_pathDelay
Path delay
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: Enter the delay [s] (smallest unit: 10 ms).
Default: 0
Access: LEVEL1
Reaction: NOTHING
Settings in the configuration editor MP number
System
Simulation
CfgSimGeneral
restartAtM99
pathDelay
114801
114802