1230 HEIDENHAIN Technical Manual MANUALplus 620
7.1.4 Access rights to NC files
You can assign access rights to NC programs (*.nc) and NC subprograms
(*.ncs). If you add an underscore as prefix before the file name (_*.nc, _*.ncs),
then the respective file will not become visible in the TNC:\nc_prog\ncps\
directory until the code number 95148 has been entered.
7.1.5 Code numbers
General
information
Press the soft key with the key symbol in the Organization operating mode in
order to enter code numbers. With these code numbers you can activate
certain functions.
Overview The following code numbers have a fixed meaning:
Code number Function
0 After access, deletion of the soft keys for the Machine
Parameter Programming, Oscilloscope and PLC
Programming operating modes.
123 Calls machine parameters that are accessible to the user.
Additional enabling of the special function for deleting all
tools ("Delete all" soft key) in the tool editor.
1234 PLC user parameters
5555 PLC Parameters
95148 Selects the Machine parameter programming mode of
operation. Additional enabling of the input fields "Set axis
values" in the menu window for the X and Y axes.
231019 Software update
049866931 Performing software updates during control start-up
through the operating system, see "NC software exchange
on the MANUALplus 620" on page 137.
531210 Deletes nonvolatile PLC operands, permanently saved
data of the PLC run-time system (e.g. feed rate limits) and
stops control operation. Then you must restart the control.
654321 OnLine Monitor (OLM)
688379 Oscilloscope
13852 Enables the commissioning tool for analog axes
(The soft key for accessing the tool is provided in the
startup screen of the internal oscilloscope.)
75368 Adjustment of analog axis offsets
807667 Selects the PLC Programming mode of operation
6871232 Tests the internal EMERGENCY STOP (as of SW02)
857282 Resets the operating times
94655 Selects the special operating mode Current Controller
and Field Angle Adjustment
NET123 Ethernet settings
SIK Opens the menu for enabling software options