260 HEIDENHAIN Technical Manual MANUALplus 620
3.24 Touch Probe Systems
The following touch probes can be connected to the MANUALplus 620:
TS 220, touch-trigger probe with cable connection for workpiece setup and
measurement during machining
TS 440, TS 444, TS 640, TS 740, touch-trigger probes with infrared
transmission for workpiece setup and measurement during machining
TT 130, TT 140, touch probes for tool measurement
For suitable connecting cables, see "Cable Overview" at the end of the chap-
ter.
X112/X113:
Triggering touch
probe
Note
The touch probes are connected to the PLB 620x PLC system module or
UEC 11x at X112 (TS) and X113 (TT).
Note
For the PLB 62xx up to and including variant -02, please note:
To connect a TT touch probe to the PLB 62xx, you have to connect the
touch probe adapter, ID 667 674-01, to X113 see "Adapter for connection
of a TT touch probe to X113" on page 263. The adapter is supplied with the
PL.
Note
The touch probes are connected to the PLB 620x PLC system module or
UEC 11x at X112 (TS) and X113 (TT).
Note
For the PLB 62xx up to variant -02, please note:
To connect a TT touch probe to the MANUALplus 620, you have to connect
the touch probe adapter, ID 667 674-01, to X113.