January 2012 3.24 Touch Probe Systems 261
X112/X113 pin layout on PLB 62xx as of variant-03 and UEC 11x (FS):
(15-pin D-sub, triple-row)
Load capacity of output voltages of X112, X113:
Socket 10, +24 V NC: max. 0.8 A
Socket 5, +5 V NC: max. 0.8 A
The currents are total currents for X112 and X113 together; they are not the
output currents per connector.
Readiness of the TS at socket 3 is detected at a voltage of +8 V NC to +24 V
NC.
Note
The interface complies with the requirements of EN 60204-1:2006 for pro-
tective extra-low voltage (PELV).
Female Assignment of X112
(TS)
Assignment of X113
(TT)
1 Trigger signal Trigger signal
2 Trigger signal
a
Trigger signal
a
3 TS ready Do not assign
4 Battery warning
Do not assign
5 + 5V NC (±5%) + 5V NC (±5%)
6 TS start Do not assign
7 TT start TT start
8 0 V NC 0 V NC
9 0 V NC 0 V NC
10 + 24 V NC + 24 V NC
11 TT ready
b
TT ready
12 Do not assign Do not assign
13 Do not assign Do not assign
14 Do not assign Do not assign
15 Do not assign Do not assign
a. Stylus at rest means logic level HIGH.
b. Only if SE 642 is configured at X112 via machine parameter
Danger
Please note that the outputs of connectors X112 and X113 are supplied
internally with 24 V NC and thus supply NC voltages derived from it at the
outputs.
For the entire HSCI system, the +24 V NC supply voltage is required to be
safely separated voltage. The +24 V NC supply voltage must not, under any
circumstances, be connected with the +24 V PLC supply voltage, because
this removes the double basic insulation.