January 2012 7.7 Override 1355
Speed override In the parameter object CfgPlcOverrideS, create a parameter set for each
spindle to which a spindle speed override is to apply.
With MP_sourceOverride define which potentiometer is to be effective
during thread cutting for speed and feed rate
MP_minimal
Minimum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 to 100.000 [%]
Default: 0
Access: LEVEL3
Reaction: RESET
MP_maximal
Maximum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 to 200.000 [%]
Default: 150
Access: LEVEL3
Reaction: RESET
MP_source
Source for override values
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name for override device from CfgPlcOverrideDev
Default:
Access: LEVEL3
Reaction: RESET
Override
potentiometer
during thread
cutting
The potentiometer adjusted with MP_sourceOverride is effective during
thread cutting for shaft speed and feed rate.
Note
If you are switching from the iTNC 530:
With MP_sourceOverride = Spindle Potentiometer you define the
iTNC 530-compatible setting for the override during thread cutting. In
milling, the feed rate during thread cutting is usually controlled with the
spindle speed override.