EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 1353

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 7.7 Override 1353
MP_source
Selection of configurable source for override values
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: OVR1
Potentiometer 1.
Feed-rate override input F on the rear side of the TE.
OVR2
Potentiometer 2.
Spindle-override input S on the rear side of the TE.
OVR3
Potentiometer 3.
Rapid-traverse override input E on the rear side of the TE.
KEY
Group of keys
Default: OVR1
Access: LEVEL3
Reaction: RESET
MP_mop
Enter the key name of the machine operating panel on which
the override source is located
Available from NCK software version: 597 110-04.
Format: Selection menu
Selection: Defines the operating panel on which the override source is
located.
Enter a key name from CfgPlcMop
Default:
Access: LEVEL3
Reaction: RESET
MP_mode
Evaluation of override values
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: DISCRETE
The key inputs or potentiometer settings are converted in up to
25 discrete override values from MP_values.
LINEAR
The input from the override device is interpolated linearly
between the minimum and maximum override value.
CURVE
The input values of the override device are converted using the
curve defined in MP_values.
You define the curve with up to 64 interpolation points in
MP_values. The input values of the override device are again
interpolated linearly above the last interpolation point specified.
If no curve is defined in MP_values, the control uses a standard
curve.
Default: DISCRETE
Access: LEVEL3
Reaction: RESET

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620

Related product manuals