234 HEIDENHAIN Technical Manual MANUALplus 620
X106 – Safety:
Single-/dual-
channel PLC
outputs (on the
front)
Connections on the front of the UxC 11x FS:
8 dual-channel PLC outputs:
O0.A to O7.A
O0.B to O7.B
8 single-channel PLC outputs:
O8.A to O15.A
Terminal Signal designation Assignm. / Function
1a O4.B 24 V outputs, can be switched off via ter-
minal X104.2a (+24 V.B)
2a O5.B
3a O6.B
4a O7.B
5a O4.A 24 V outputs, can be switched off via ter-
minal X104.1a (+24 V.A)
6a O5.A
7a O6.A
8a O7.A
9a O12.A 24 V outputs, can be switched off via ter-
minal X104.3a (+24 V.C)
10a O13.A
11a O14.A
12a O15.A
1b O0.B 24 V outputs, can be switched off via ter-
minal X104.2a (+24 V.B)
2b O1.B
3b O2.B
4b O3.B
5b O0.A 24 V outputs, can be switched off via ter-
minal X104.1a (+24 V.A)
6b O1.A
7b O2.A
8b O3.A
9b O8.A 24 V outputs, can be switched off via ter-
minal X104.3a (+24 V.C)
10b O9.A
11b O10.A
12b O11.A
Each output of the UxC 11x (FS) can be loaded with a maximum current of
150 mA.
If the integrated PLC outputs do not suffice for your application, you can
connect up to 7 additional external PL 61xx expansion PLs to the
UxC 111FS via the HSCI interface.