EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 1150

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1150 HEIDENHAIN Technical Manual MANUALplus 620
Setup for digital
signals
Call the "M, I, O, T, C selection" dialog box:
Press the SELECT MIOTC soft key.
Set:
Operand: Type and number of the PLC operand’s symbolic name
•M: Marker
I: Input
•O: Output
•T: Timer
•C: Counter
X: Diagnostic information for internal purposes
s: Symbolic API operand
After selection, the symbolic API operand can be selected over the
SYMBOL LIST soft key.
Trigger:
X: No trigger
0: Trigger at 0-level
1: Trigger at 1-level
The trigger is only taken into consideration if Selection=X is set.
Selection:
X: Signal is displayed and considered as trigger
Empty field: Signal is not displayed and not considered as trigger
Note
You define the general trigger conditions ("Trigger" input field) and the
pre-trigger in the setup for analog signals.
The trigger condition "logic" is fulfilled when all triggers set in "M I O T C
selection" are fulfilled (AND-gating).

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620

Related product manuals