1152 HEIDENHAIN Technical Manual MANUALplus 620
Starting signal
recording before
the first PLC scan
To start the signal recording in the oscilloscope before the first PLC scan,
proceed as follows:
Start the control.
Do not acknowledge the Power interrupted message with the CE key;
instead, enter the code number 807667 to switch to the PLC programming
mode of operation.
Press the COMPILE soft key.
Press the SELECT + COMPILE PLC PGM soft key and press the SELECT soft key
to compile the MAIN_PGM.SRC PLC main program manually. The "PLC
program could not be started" error message can be ignored.
Select the desired data in the oscilloscope and press the START soft key to
start recording.
Acknowledge the power interruption with the CE key.