1214 HEIDENHAIN Technical Manual MANUALplus 620
Generating an
asynchronous
position
compensation (Set
PosCorr)
The Set PosCorr function generates an asynchronous position compensation
(additive compensation). You define the number of the compensation and the
compensation values.
To select the Set PosCorr function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the Auxil soft key.
Press the Set PosCorr soft key for the OLM to open the "Send
asynchron Pos-Corr" dialog box (see figure below).
Enter the required data in the dialog box (see below).
Confirm with OK—the OLM generates the compensation.
"Send asynchron Pos-Corr" dialog box:
Dialog box entries:
ID: Compensation number
dX, dY, dZ: Compensation values