January 2012 6.22 Diagnosis with the Online Monitor (OLM) 1217
The function displays the values measured by the analog inputs as well as the
permissible limits of some temperature and voltage values:
Value column: Measured values, converted to units used internally by the
PLC
Raw value column: Values from the encoder, standardized to 16-bit format
Constraint column: Limit values
Sample interval column: PLC interval during which the value was read
(0=simulated value)
Displays:
Variable Display
ovr1
ovr2
Values of the override potentiometer (* 10000)
battery Battery voltage (* 1000)
goldCap "Gold-cap" voltage (* 1000)
caseTemp Temperature of the control (* 10)
supply5V 5 V supply voltage at the main board (* 1000 / 2)
supply3V 3.3 V supply voltage at the main board (* 1000)
pt100_1
..
pt100_3
Temperature inputs (X48) of the MC (* 10)
u_1
..
u_3
Voltage of the analog inputs (X48) of the MC (* 1000)
tempCpu1 Temperature of CPU 1 (* 10)
tempCpu2 Temperature of CPU 2 (* 10)
caseFan Fan speed [rpm]