1232 HEIDENHAIN Technical Manual MANUALplus 620
With MP_hideOriginal, define whether the previous HEIDENHAIN code
number remains effective or is deactivated
Save your changes with the SAVE soft key.
The new code number is immediately effective.
MP_replaceWith
New OEM password or code number
Available from NCK software version: 597 110-05.
Format: String
Input: Max. 18 characters
Numerals and/or capital letters
The HEIDENHAIN password indicated in the key name is
replaced by the new OEM password defined here.
Default: No value, parameter optional
Access: LEVEL3
Reaction: NOTHING
MP_hideOriginal
Lock previous HEIDENHAIN code number
Available from NCK software version: 597 110-05.
Format: Selection menu
Selection: TRUE
The previous HEIDENHAIN code number is disabled.
FALSE
The previous HEIDENHAIN code number remains in effect.
Default: No value, parameter optional
Access: LEVEL3
Reaction: NOTHING
Warning
If you set MP_hideOriginal = TRUE, then if the new code number is lost,
only HEIDENHAIN service personnel can restore the previous
HEIDENHAIN code number.
Protect the new code number from loss!