1272 HEIDENHAIN Technical Manual MANUALplus 620
Module 9085 Display PLC error message
The module transfers PLC error messages to the error system. The error 
message texts come directly from the compiled error table (.PET) or from the 
selected text file for PLC error messages. PLC error messages (except reset 
errors) can be deleted by Module 9086 or by the user. However, deletion can 
be disabled in the error table ("CE" column).
Up to 32 error messages can be placed in the queue.
If an error marker is assigned to the error, it is set.
System error: Is displayed without entry in the queue.
Error number –1: System error message EMERGENCY STOP PLC is displayed. This 
error message also occurs if no *.PET table was defined.
Error number not equal to –1 and no *.PET table selected: 
System error message PLC: ERROR TABLE MISSING
Call:
PS B/W/D/K <Line number of the *.PET table>
0 to 999: Line number
–1: System error message EMERGENCY STOP PLC
CM 9085
Error recognition: 
Marker Value Meaning
NN_GenApiModule
Error
0 Error message displayed or in queue
1 Error code in NN_GenApiModuleErrorCode
NN_GenApiModule
ErrorCode
1 Line number missing
8 Incorrect operating mode, compatibility 
error marker set
23 Overflow of PLC error message queue, or 
too many error messages from string 
memory