1296 HEIDENHAIN Technical Manual MANUALplus 620
Overview of the
available
dashboard
elements
The following table lists the available dashboard elements and the associated
attributes.
Image Name Display/Attribute
Handwheel active
Clamping active
ActualValue
[DB_X1_POS,
DB_Y1_POS,
DB_Z1_POS,
DB_W1_POS]
Display: Current position of an axis (actual-
value display), handwheel and clamping
are active
Letter designating the axis appears in
black: Axis enabled by controller
Letter designating the axis appears in
white: Axis disabled by controller
Attributes:
Bit 0=0: Display the position of the tool
tip
Bit 0=1: Display the IPO axis value—
identified by "I" after the letter
designating the axis. Tool lengths and
datum shifts are not considered.
Bit 1=0: Display only if reference run has
occurred
Bit 1=1: Display even if no reference run
has occurred
Bit 2=1: Following error is displayed
(code L)
With the General display settings -> Axis
display or MP_axesDisplayMode user
parameter, the position display can be
adapted, whereby the attribute settings
are then without effect.
Selection:
Default: No effect, attribute settings are
without effect
ActualValue: Actual position (REF ACTL)
with respect to the machine datum
(code A)
NominalValue: Nominal position (REF
NOML) with respect to the machine
datum (code N). This value corresponds
to the interpolator axis value (code I) if bit
0=1
Lag: Following error (code L)
Distance: Distance to go (code D)