January 2012 7.7 Override 1357
Feed rate override
In the channel-sensitive parameter object CfgPlcOverrideF, create a
parameter set for each machining channel (slide) to which a feed rate
override is to apply.
MP_minimal
Minimum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.00 to 100.00 [%]
Default: 0
Access: LEVEL3
Reaction: RESET
MP_maximal
Maximum value for override
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.00 to 200.00 [%]
Default: 150
Access: LEVEL3
Reaction: RESET
MP_source
Source for override values
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Key name for override device from CfgPlcOverrideDev
Default: PotentiometerF
Access: LEVEL3
Reaction: RESET
Settings in the configuration editor MP number
Channels
ChannelSettings
[Key name of the machining channel]
CfgPlcOverrideF
minimal
maximal
source
201901
201902
201903
Note
The feed rate override also applies to rapid traverse if the rapid traverse
override is not active.