1362 HEIDENHAIN Technical Manual MANUALplus 620
Module 9137 Read diagnostic information of the PL 510
The module provides diagnostic information about the PL 510. To save 
computing time, refrain from continuously calling this module.
Call:
PS B/W/D/K <Number of the PLB 510 basic module (0 to 3)>
PS B/W/D/K <Number of the slot (0 to 3)>
PS B/W/D/K <Number of the information>
0: Possible mode of operation (PL modular mode)
1: Active mode of operation
2: Reserved
3: Reserved
4: Basic module code
5: Status of the basic module
6: Module type in the slot
7: Reserved
8: Reserved
9: Status of the module in the slot
10: Logical status of the outputs of a PLD 16-8
11: Short-circuit of the outputs of a PLD 16-8
12: Number of connected PL 510
CM 9137
PL W/D <Diagnosis information>
Information no. 0:
0: "PL 510" operating mode not possible (only "PL 4xxB" 
operating mode, without new functions of the PL 510)
1: "PL 510" operating mode possible
Information no. 1:
0: "PL 4xxB" operating mode active (without new 
functions of the PL 510)
1: "PL 510" operating mode active
Information no. 2:
0: No PLB 510
1: PLB 510
Information no. 3:
0..15: Hardware version
Information no. 4:
0..15: Hardware code
Information no. 5:
Bit 0 = 1: Power supply of the PLB 510 is OK
Bits 1 to 15: Reserved
Information no. 6:
0: No module in slot
1: Reserved
2: PLD 16-8
3: PLA 4-4 in slot
Information no. 7:
0..15: Hardware version (identifies the function status of 
the module)
Information no. 8:
0..15: Hardware code (identifies a hardware change 
state)
Information no. 9:
PLD 16-8 (module type 2):
Bit 0 = 1: Power supply outputs 0 to 3 are OK
Bit 1 = 1: Power supply outputs 4 to 7 are OK