1420 HEIDENHAIN Technical Manual MANUALplus 620
MP_DefaultCLT
Settings for "Coolant CLT" in the start unit
Available from NCK software version: 597 110-03.
Format: Numerical value
Input: 0: Without
Default setting: Do not activate a coolant circuit
1: Coolant 1 on
Default setting: Activate coolant circuit 1
2: Coolant 2 on
Default setting: Activate coolant circuit 2
Default: 1
Access: LEVEL1
Reaction: RUN
MP_DefaultG60
Settings for "Protective zone G60" in the start unit
Available from NCK software version: 597 110-03.
Format: Numerical value
Input: 0: Active
Default setting: G60 Q0
1: Inactive
Default setting: G60 Q1
Default: 0
Access: LEVEL1
Reaction: RUN
MP_DefGlobG47P
Global "Safety clearance G47" for the start unit. The "G47 P.." of
the machining unit is generated with this safety clearance.
Available from NCK software version: 597 110-03.
Format: Numerical value
Input: Safety clearance in [mm] with up to 9 decimal places
Default: 2 [mm]
Access: LEVEL1
Reaction: RUN
MP_DefGlobG147SCI
Global "Safety clearance plane SCI" for the start unit. The "I" of
the "G147 I.. K.." call of the machining unit is generated with this
safety clearance.
Available from NCK software version: 597 110-03.
Format: Numerical value
Input: Safety clearance in [mm] with up to 9 decimal places
Default: 2 [mm]
Access: LEVEL1
Reaction: RUN