1440 HEIDENHAIN Technical Manual MANUALplus 620
To display the current position and distance-to-go of the Y axis in the
dashboard, change the entries in the lists opmodeStartup,
opmodeReference, opmodeManual and opmodeAutomatic of the entity
CfgChannDashboard as follows.
Switch off the test mode of the Y axis by entering MP_testMode =FALSE.
Please remember that the Y axis must be connected electrically if
MP_axisMode = Active. In this case, you should also verify if a speed
encoder input is assigned to the Y axis in MP_speedEncoderInput, and a
nominal speed command output in MP_pwmSignalOutput.
Settings in the configuration editor MP number
Channels
ChannelSettings
[Key name of the machining channel]
CfgChannDashboard
opmodeStartup
[0]: DB_STARTUP1_Y
opmodeReference
[0]: DB_REFER1_Y
opmodeManual
[0]: DB_MANUAL1_Y
opmodeAutomatic
[0]: DB_AUTO1_Y
203402
203403
203404
203406
Settings in the configuration editor MP number
Axes
PhysicalAxis
[Y1]
CfgAxis
testMode Y1.300106