1512 HEIDENHAIN Technical Manual MANUALplus 620
REMMARKERMAX End address of the markers whose data
remains stored after a power interruption
(remanence).
The range defined by REMMARKERMIN and
REMMARKERMAX may not consist of more
than 2048 markers.
Default value: –1 = Deactivated
REMMARKERMAX = 150
MARKERS A total of 100 000
bytes is available
for all keywords,
timers, counters
and strings
combined
Number of markers
available.
Default value: 10000
MARKERS = 15000
BYTES Size in bytes for the
byte/word/double word
memory.
Default value: 10000
BYTES = 20000
INPUTS Number of input
markers available.
Default value: 384
INPUTS = 450
OUTPUTS Number of output
markers available.
Default value: 192
OUTPUTS = 250
INPUTBYTES Size in bytes for the
byte/word/double word
memory range used by
the Profibus inputs.
Default value: 1000
OUTPUTBYTES Size in bytes for the
byte/word/double word
memory range used by
the Profibus outputs.
Default value: 1000