January 2012 8.4 Operands 1527
MP_run
Process marker for the timer or counter
Available from NCK software version: 597 110-03.
Format: String 
Input: Max. 80 characters
Identifies the timer or counter (process marker), for which the 
respectively configured time applies. 
Timer: T48 to T999
Counter: C48 to C95
If two or more times are configured, the parameter identifies 
the first timer or counter.
Default: No entry, value optional
Access: LEVEL3
Reaction: NOTHING
MP_start
Start marker for the timer or counter
Available from NCK software version: 597 110-03.
Format: String 
Input: Max. 80 characters
Identifies the start marker for the timer or counter. 
Timer: T0 to T47
Counter: C0 to C47
There is no start marker for timers T96 to T999. They can be 
started only through Module 9006.
This parameter is not evaluated by the control. The 
PLCdesignNT development environment uses it for the 
automatic generation of PLC definition files.
Default: No entry, value optional
Access: LEVEL3
Reaction: NOTHING
C39 C87 C135 counter[39]
C40 C88 C136 counter[40]
C41 C89 C137 counter[41]
C42 C90 C138 counter[42]
C43 C91 C139 counter[43]
C44 C92 C140 counter[44]
C45 C93 C141 counter[45]
C46 C94 C142 counter[46]
C47 C95 C143 counter[47]
Start 
counter
Counter is 
running
Enable 
counter
Machine parameters