January 2012 8.4 Operands 1533
MP_significance
Activation criterion for fast PLC inputs
Format: Selection menu
Selection: lowActive
Activate at LOW level
highActive
Activate at HIGH level
allEdges
Activate at both levels
disabled
Switched off
Default: disabled
Access: LEVEL3
Reaction: RUN
MP_operand
PLC operand for fast PLC inputs
Format: Array [0...4]
Input: A string with max. 24 characters can be entered for each array.
Example:
NN_FastInput_01
Default: NN_FastInput_01 to NN_FastInput_05
Access: LEVEL3
Reaction: RUN