EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 1550

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1550 HEIDENHAIN Technical Manual MANUALplus 620
MP_min
Code of the first M function
Format: Numerical value
Input: 0 to 9999
First M code described in the parameter object. The properties
described in this parameter object apply for the specified M
functions.
Default: 0
Access: LEVEL3
Reaction: RESET
MP_max
Code of the last M function
Format: Numerical value
Input: 0 to 9999
Code of the last (greatest) M function described in the
parameter object.
No entry: The properties of the parameter object apply only to
the M function defined in MP_min.
Default: No entry, value optional
Access: LEVEL3
Reaction: RESET
Transfer and
acknowledgment of
M function
In the Program Run, Full Sequence and Program Run, Single Block operating
modes, the next NC block is not run until the PLC has acknowledged
execution of the M function.
There are two possibilities for transferring the M strobe to the PLC and for
acknowledgment by the PLC:
Transfer and acknowledgment with MP_signal
Transfer of the M strobe: The PLC marker defined in MP_signal is set
Acknowledgment of the M strobe: The PLC marker defined in
MP_signal is reset.
Transfer with MP_signal and acknowledgment with MP_acknowledge:
Transfer of the M strobe: The PLC marker defined in MP_signal is set
Acknowledgment of the M strobe: The PLC marker defined in
MP_acknowledge is set.
HEIDENHAIN recommends that you only use MP_signal for transfer and
acknowledgment.
If MP_signal and MP_acknowledge are not defined, the data of the M strobe
are saved without synchronization with the PLC program. The output is
immediately acknowledged.