1598 HEIDENHAIN Technical Manual MANUALplus 620
MP_columnKeys
List of column names
Available from NCK software version: 597 110-01.
Format: Array [0...]
Input: xxx.xxx
Name of the column in uppercase letters in the format <table
extension>.<column name>;
Max. 20 characters
Default: -
Access: LEVEL3
Reaction: NOTHING
MP_primaryKey
Name of the column, based upon which the data is sorted in
ascending order
Available from NCK software version: 597 110-01.
Format: String
Input: <Column name>
Max. 18 characters
Name of the column must also be entered in MP_columnKeys.
Default: -
Access: LEVEL3
Reaction: NOTHING
MP_foreignKey
Specify a character string of the type <column
name><blank><referential action> for each list item.
Format: Array [1...79]
Input: Valid values for <referential action> are NO ACTION,
RESTRICT, SET NULL, SET DEFAULT and INHERIT.
Max. 40 characters
Default: -
Access: LEVEL3
Reaction: NOTHING
MP_modificationKey
Enter the key name of the column in which the timestamp is to
be entered if the line is modified
Format: String
Input: <Table extension>.<column name>;
Max. 18 characters
Default: -
Access: LEVEL3
Reaction: NOTHING