1616 HEIDENHAIN Technical Manual MANUALplus 620
Error recognition:
Marker Value Meaning
NN_GenApiModule
Error (M4203)
0 Editor was opened
1 Error code in NN_GenApiModuleErrorCode
(W1022)
NN_GenApiModule
ErrorCode (W1022)
1 – Invalid values for the strings for file name
and field name were transferred
– The range defined by the entries for first
and last line is not logical. Possibilities
include start>end, or start after file end, or
the given file is an empty document, or the
start and/or end contain negative values.
– Values for additional parameters were
given, which is not permitted in this context,
or options which are only intended for
complete files were activated for a partial file
(not all lines/columns)
6 A write-protected file cannot be opened with
transferred write-protection (bit 3).
7 The given file cannot be read from, or the
temporary file cannot be created.
8 The module was called during an NC
operating mode in which the table editor
cannot be started.
20 The module was called from the cyclic
program part.
28 A file has already been opened by the PLC
for editing
29 The given file does not exist or is not of the
type .TAB or .P.
30 The given field names do not exist in the
given file.
36 An invalid file name or file type was
programmed.