EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 169

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 3.4 HSCI 169
The following table shows the maximum permissible number of individual
HSCI participants:
The order of the HSCI participants at X500 of the main computer can be freely
chosen. Each HSCI participant is assigned its HSCI address based on its posi-
tion in the HSCI chain:
First device after the master (main computer): Bus address 1
Second device after the master (main computer): Bus address 2 etc.
The main computer selects a master controller unit, based on the position of
the controller units in the HSCI network. The first controller unit in the system
(nearest the main computer) becomes the master controller unit.
HSCI component Maximum number
MC
(HSCI master)
1 in the system
CC, UEC, UMC
(HSCI slave)
4 drive-control motherboards,
(distributed to CC, UEC, UMC as desired)
MB 6xx (FS),
PLB 6001 (FS)
(HSCI slave)
2 in the system Total number of
9 components
must not be
exceeded in this
case
PLB 62xx (FS)
(HSCI slave)
1 in the system
(not with UEC 11x)
PLB 61xx (FS),
PLB 62xx (FS)
(HSCI slave)
7 in the system
HR (FS) handwheel
(at the MB 6xx or
PLB 6001)
1 in the system
PLD-H xx-xx FS
(in PLB 6xxx FS)
8 in the system
PLD-H xx-xx
(in PLB 6xxx FS)
64 in the system
Danger
If you use more than one operating station or machine operating panel, the
PLC program must ensure that only one of the operating devices is active
at any one time so as to avoid danger to the operator.