1754 HEIDENHAIN Technical Manual MANUALplus 620
Module 9020/9021/9022 Write in the word range
The control writes the specified byte, word or double word to the defined
location in the word memory. Indexed writing is possible by specifying a
variable as designation of the memory location.
Call:
PS B/W/D/K <Address of the byte to be written>
PS B/W/D/K <Byte to be written>
CM 9020 ; WRITE BYTE TO ADDRESS
PS B/W/D/K <Address of the word to be written>
PS B/W/D/K <Word to be written>
CM 9021 ; WRITE WORD TO ADDRESS
PS B/W/D/K <Address of the double word to be written>
PS B/W/D/K <Double word to be written>
CM 9022 ; WRITE DOUBLE WORD TO ADDRESS
Error recognition:
Example of
Module 9020
Initial state:
Byte B10 = 35 (address)
Byte B100 = 120 (byte to be written)
Byte B35 = ?
Marker Value Meaning
NN_GenApiModule
Error (M4203)
0 Byte was written
1 Error code in NN_GenApiModuleErrorCode
(W1022)
NN_GenApiModule
ErrorCode (W1022)
3 Invalid address was programmed
5 Module 9021: Specified address is not a
word address
Module 9022: Specified address is not a
double word address
Function STL Accumulator
content (dec)
Data stack (dec)
Save the address
(B10) of the byte to
be written from the
word accumulator in
the data stack
PS B10 35 35
Save byte B100 from
the word
accumulator in the
data stack
PS B100 120 120
Write data stack to
byte B35
CM 9020 120