1792 HEIDENHAIN Technical Manual MANUALplus 620
MP_timeout
Timeout in minutes for transmission of the message to the
remote service host
Available from NCK software version: 597 110-03.
Format: Numerical value
Input: 0 to 15 [min]
Default: No value, parameter optional
Access: LEVEL2
Reaction: NOTHING
MP_serverIp
Network address or host name of the server
Available from NCK software version: 597 110-03.
Format: String
Input: Max. 500 characters
The data traffic of the specified server(s) is checked. The default
value is the server given in the MP_host parameter.
Default: No value, parameter optional
Access: LEVEL2
Reaction: NOTHING
MP_serverIpMask
Subnet mask of the server network
Available from NCK software version: 597 110-03.
Format: String
Input: Max. 500 characters
Enter the subnet mask of the server as four decimal numbers
separated by periods (IP address in dotted-decimal notation).
Default: No value, parameter optional
Access: LEVEL2
Reaction: NOTHING