January 2012 1.2 NC Software 548 328-02 21
 Replacing the apimarker.def file:
During the update of the NC software, a new version of the apimarker.def 
file was automatically copied to the PLC partition of the control.  Proceed as 
follows:
 Switch to the Organization mode of operation.
 Enter the code number 95148 to call the Machine Parameter mode of 
operation.
 Press the END soft key and switch the soft-key row.
 Press the PGMMGT   soft key to open the file manager.
 Switch to the PLC:\proto\plc directory.
 Copy the apimarker.def file to the program directory of your PLC program. 
Overwrite the existing apimarker.def file:
 
 
You also need to copy the apimarker.def file to your PC, and add it to the 
PLCdesignNT project. Otherwise, during the next transfer of PLC project 
files to the control, the file might be overwritten by the old version.
After an update, please modify the previous file oem_turning.mcg as 
described below, and add it to the PLCdesignNT project. Otherwise, during 
the next transfer of PLC project files to the control, the file 
oem_turning.mcg might be overwritten by the old version, which leads to 
an error.