EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 273

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 3.26 MB 620T Machine Operating Panel 273
X31: MB 620T,
permissive button /
NC start / NC stop
Standard wiring of connection X31 for MB 620T without FS:
Pin layout of MB 620T FS:
NC Start and NC Stop are normally-open contacts on the MB 620 (FS).
Connecting
terminals
Assignment
1 Reserved (do not use)
2 Reserved (do not use)
3 Reserved (do not use)
4 Reserved (do not use)
5 NC Start
a
a. With standard wiring
6 Reserved (do not use)
7 NC Start power supply (+24 V NC)
a
8NCStopa
9 Reserved (do not use)
10 NC Stop power supply (+24 V NC)
a
Connecting
terminals
Assignment
1 Optional: Permissive key channel A / terminal 1 (+24 V)
2 Optional: Permissive key channel A / terminal 2
3 Optional: Permissive key channel B / terminal 1 (+24 V)
4 Optional: Permissive key channel B / terminal 2
5 NC Start channel A / terminal 1 a
6 NC Start channel B / terminal 2 a
7 NC Start shared terminal (+24 V NC)a
8 NC Stop channel A / terminal 1a
9 NC Stop channel B / terminal 2a
10 NC Stop shared terminal (+24 V NC)
a
a. With standard wiring
Danger
Please note that the MB 620T is powered by +24 V NC.
For the entire HSCI system, the +24 V NC supply voltage is required to be
safely separated voltage. The +24 V NC supply voltage must not, under any
circumstances, be connected with the +24 V PLC supply voltage, because
this removes the double basic insulation.