January 2012 3.27 HSCI Adapter for PLB 6001 OEM-Specific Machine Operating Panel 279
PLB 6001 pin layout Connect
or
Function Page
X500 HSCI output 171
X502 HSCI input 171
X6 PLC inputs 281
X7 PLC outputs 280
X10 Interface to keyboard and potentiome-
ters
282
X18 Reserved
X23 Handwheel connection 287
X30 Reserved
X31 Permissive key, NC Start, NC Stop 283
X101 24 V NC power supply 275
X111 Potentiometer connection 1 286
X112 Potentiometer connection 2 286
X113 Potentiometer connection 3 286
X121 Reserved
X122 Reserved
X123 Reserved
X161 PLC inputs I0 to I7 285
X162 PLC inputs I8 to I15 285
X163 PLC inputs I16 to I23 285
X164 PLC inputs I24 to I31 285
X165 PLC inputs I32 to I39 285
X166 PLC inputs I40 to I47 285
X167 PLC inputs I48 to I55 285
X168 PLC inputs I56 to I63 285
X171 PLC outputs O0 to O7 286
X172 PLC outputs O8 to O15 286
X173 PLC outputs O16 to O23 286
X174 PLC outputs O24 to O31 286
Protective ground 286
Warning
Do not engage or disengage any connecting elements while the unit is
under power!
X10
X101
X7 X6 X31
X30
X502
X500
X23
X18
X123
X122
X121
X113
X112
X111
X174 X173 X172 X171
24V
+
X161X162X163X164X165X166X167X168