January 2012 4.2 The "Machine Parameters" Mode of Operation 349
Reaction RESET
After a machine parameter to which the RESET reaction is assigned has been
changed, the error message Machine parameters were changed. Shut down
and restart the control is displayed.
This message cannot be cleared. The machine must be restarted. If you want
to make more changes in the configuration editor, you can also perform the
restart later.
Data objects with this reaction must not be changed during program run.
Reaction REBOOT
Basically, the same characteristics apply as for the RESET reaction. However,
the behavior during shutdown is different. If a parameter with the REBOOT
reaction is changed, the saving of the configuration data will lead immediately
to a restart of the control. In contrast to the RESET reaction, no error message
is displayed.