388 HEIDENHAIN Technical Manual MANUALplus 620
Basic data This view shows the data imported during system start-up. Any changes will
be rewritten to the respective basic files.
Loaded subfile(s) You must have loaded a subfile during system start-up (with "CfgPortionFiles")
or by soft key for the subfile to be shown. If you select a subfile, only the data
of the subfile are displayed in the configuration editor.
The attributes contained in the subfile can be edited and rewritten to the
subfile while saving.
The subfile must be reloaded for the edited data to become effective.
Temporary data The complete data objects of all loaded subfiles are shown. They can be
edited, but they are not rewritten to the file. If a subfile from the PLC is loaded,
the data is saved only as temporary data.
Effective data The "effective data" view does not permit data to be edited. The displayed data
refer to the current data loaded by the PLC or by selecting the data record of
basic data or subfiles, and therefore show the data effective in the system.
Exception: Configuration data written with FN17 are not shown in this view.
Unload subfile The UNLOAD soft key can be used to unload the selected subfile.
This automatically activates the basic data and the subfiles that are still loaded.
The result is also shown in "Temporary data" and "Effective data."