390 HEIDENHAIN Technical Manual MANUALplus 620
Supplementary explanations for calling Modules 9430 to 9433, 9436 and 9438:
Entries for PS/PL Description of the module entries
<Name of the 
configuration 
object>
Name of the folder in the machine configuration (= 
config object or entity), in which the machine 
parameter to be changed is located;
e.g.: "CfgOemBool"
<Key name> Key name where the object is located; e.g. 
"CH_NC".
Key names are used to structure the machine 
configuration – they gather associated areas 
together, such as a machining channel ("CH_NC") or 
the parameter set of an axis ("PX").
Transfer an empty string for parameters without 
key names.
<Name of the 
machine 
parameter>
Name of the machine parameter (attribute) that is 
to be changed; 
e.g.: "swLimitSwitchPos"
<Index> Index within an array (list field); 
Enter 0 for parameters without an array
<Factor> Division factor for conversion to a floating-point 
number
Enter 1 to receive integer parameters
<Value of the 
machine 
parameter>
Value of the parameter, e.g.: 123456
<String> String number (0 to 15)
<Errors> See "Return codes of PLC Modules 9430 to 9433, 
9436, 9438 (error stack)" on page 397.