January 2012 6.2 Configuration of Machining Channels 623
To move to the restore position:
In MP_restoreAxis, specify the sequence in which the axes are to move.
MP_restoreAxis
Sequence for returning to the contour
Available from NCK software version: 597 110-03.
Format: Selection menu
Selection: The key names of the axes are taken from the System/CfgAxes/
axisList parameter and automatically shown as a selection
menu.
Default:
Access: LEVEL3
Reaction: RESET
In MP_restoreFeed, specify the feed rate at which positions are to be
approached.
MP_restoreFeed
Feed rate for returning to the contour
Available from NCK software version: 597 110-02.
Format: Numerical value
Input: Feed rate in [mm/min] or [°/min] for returning to the contour
after an NC stop or block scan.
Default: 1200 [mm/min] or [°/min]
Access: LEVEL3
Reaction: RUN