January 2012 6.3 Configuration of Axes 635
Setting the drive 
interface
Use the MP_axisHw machine parameter to define the drive interface. The 
parameter defines the hardware type of the axis at the time of the control 
startup. The parameter is evaluated only if the value "active" was entered in 
MP_axisMode.
MP_axisHw
Hardware to which the axis is connected
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: None
No hardware connection (virtual axis)
InOutCC
Digital axis with connection to a controller unit
AnalogMC
Analog drive interface; encoder connection to the MC
AnalogCC
Analog drive interface; encoder connection to the CC
DisplayMC
Display axis; encoder connection to the MC
DisplayCC
Display axis; encoder connection to the CC
ManualMC
Open-loop axis; encoder connection to the MC
ManualCC
Open-loop axis; encoder connection to the CC
ProfiNet
Digital Profinet axis (reserved, function not available yet)
Default: InOutCC
Access: LEVEL3
Reaction: RESET