644 HEIDENHAIN Technical Manual MANUALplus 620
Configuring a 
manual axis
 For the manually operated axis, set the MP_axisHw and MP_axisMode 
machine parameters to the values indicated in the table.
 Because the control itself cannot move the axis over the reference marks, 
the reference run mode must be set accordingly:
With MP_refType you can either set the value distance coded + on the 
fly or without switch + on the fly as the reference run mode..
 Deactivate standstill monitoring. Set MP_checkPosStandstill = 0.
 Deactivate movement monitoring for the axis: Set 
MP_movementThreshold = 0.
Settings in the configuration editor Input:
Axes
PhysicalAxis
[Key name of the axis]
CfgAxis
axisHw
axisMode
ParameterSets
[Key name of the axis]
CfgReferencing
refType
CfgControllerAuxil
checkPosStandstill
CfgEncoderMonitor
movementThreshold
CfgControllerTol
posTolerance
ManualMC or ManualCC
Active
distance coded + on the fly or
without switch + on the fly
0
0
Desired positioning window