662 HEIDENHAIN Technical Manual MANUALplus 620
MP_speedEncoderInput
Assignment of a speed encoder input to the axis
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: none
No speed encoder connected
X15...X20
Speed encoder inputs are X15 to X20
X80...X83
Speed encoder inputs are X80 to X83
Default: none
Access: LEVEL3
Reaction: RESET
MP_inverterInterface
Assignment of the speed command output to the axis
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: none
Not a PWM output, no power module connected
X51...X56
PWM outputs are X51 to X60
X80...X85
Only on UEC 11x: Motor connections are X80 to X85
Default: none
Access: LEVEL3
Reaction: RESET
MP_posEncoderInput
Assignment of a position encoder input to the axis
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: none
No position encoder connected
X01...X06
Position encoder inputs are X01 to X06 (on the MC 42x)
X35...X38
Position encoder inputs are X35 to X38 (on the MC 42x)
X201...X210
Position encoder inputs are X201 to X210 (on the CC)
Default: none
Access: LEVEL3
Reaction: RESET